Radiation shielding stops or attenuates ionising radiation so that operators and the public stay within dose limits. Lead remains the default shielding material because of its high density and predictable attenuation per millimetre. This guide covers the common product forms and how to specify them without over- or under-building the barrier.
Lead sheet is supplied in rolls or flat plates, with thickness stated as an equivalent millimetres of lead (mm Pb). Attenuation rises with thickness and with the energy of the radiation: a given mm Pb blocks low-energy diagnostic X-rays far more effectively than high-energy industrial gamma. Specify the required mm Pb equivalence for the highest energy present, not an average.
Lead glass provides a viewing window while maintaining shielding. It is rated by lead equivalence (e.g. 0.5–2.0 mm Pb) and must be framed in a compatible shielded frame so the joint does not become a leak path. Handle it as a fragile, heavy optic: support the full pane and avoid point loads.
Lead-lined doors (sliding or hinged) close off room openings while preserving the shield. Key choices are the lead equivalence, the frame and seal detail, and whether the door carries a viewing panel. For large openings, sliding lead doors on a shielded track are common in imaging suites.
Interlocking lead bricks build temporary or reconfigurable shielding walls in labs and NDT bays. Machined or cast lead blocks serve isotope containers and collimators where geometry matters.
A complete request states: the radiation type and maximum energy, the required shielded area and any openings, the target dose limit, the door and window positions, and the applicable standard. We supply lead sheet, lead glass, lead doors and bricks for medical and industrial shielding; for a quotation in English, contact our team with the room layout and the required mm Pb equivalence.
No. Concrete, barium plaster and tungsten-loaded polymers are used where space or weight matters, but lead remains the most common choice for its density, workability and cost balance.
Thickness follows from the radiation energy and the dose limit you must meet; a shielding calculation against the relevant standard gives the required mm Pb. Provide the energy and room use and a supplier can size it.
Sheet can be cut with care and proper dust control; lead glass should be cut only by the supplier to avoid edge chipping and to keep the pane supported.