Feiyan supplies NiTi shape memory alloy (nitinol) in superelastic and thermal-activation grades: straight and set-trained wire, hypotube and superelastic tube, strip and sheet, plus custom-formed actuators. Transformation temperatures (Af) are selectable from 20 °C to 90 °C; medical grades per ASTM F2063 are available with full traceability.



▲ Precision alloy wire / plate stock
• Superelastic NiTi wire — Ø0.05–3.0 mm, straight or coil-set, for guides, frames and antennas
• Thermal-activation (shape memory) wire — Af 20–90 °C, trained two-way shapes
• NiTi tube — OD 1–8 mm, wall 0.1–0.5 mm, for medical hypotubes and couplings
• NiTi sheet & strip — 0.1–2 mm, for washers, rings and stamped parts
• Custom actuators & assemblies — bent, trained and heat-treated to your drawing
| Property | Superelastic Grade | Shape-Memory Grade |
|---|---|---|
| Nickel content | 55.4–56.5 wt% Ni (balance Ti) | 55.4–56.5 wt% Ni (balance Ti) |
| Af temperature | ≤ −20 °C (body-temperature superelastic) | 20 °C – 90 °C selectable |
| Tensile strength (annealed) | ≥ 900 MPa (up to 1300 MPa work-hardened) | ≥ 800 MPa |
| Recoverable strain | up to 8% | up to 6% (one-way memory) |
| Fatigue life | ≥ 10⁶ cycles at 2% strain (typical) | ≥ 10⁴ thermal cycles (typical) |
| Standard | ASTM F2063 (medical) available | ASTM F2063 (medical) available |
Af temperature custom-tuned per melt and verified by DSC · medical-grade melts with full melt traceability · precision laser cutting and shape setting in-house · small MOQ for R&D, stable mass-production capacity through partner lines.
Medical devices (guidewires, stents, orthodontic archwires, retrieval baskets) · eyeglass frames · antennas and consumer wearables · thermal actuators, valves and clamps · aerospace pipe couplings · fire-safety and temperature-indicating mechanisms.
Sputtering Targets · High-Purity Metals · Radiation Shielding · Rare Metals · Medical Materials · Lightning Protection & Grounding · Precious Metal Recycling
Q: How do I choose the Af temperature for an actuator?
A: Pick Af 5–10 °C above your maximum ambient/off-state temperature so the part stays deformed until triggered, and confirm the shape-recovery stroke against the part geometry. We tune each melt to your specified Af and verify by DSC before shipping.
Q: Is medical-grade nitinol available?
A: Yes, ASTM F2063-compliant melts with certificate of analysis and full melt traceability are available for guidewire, stent and orthodontic applications.
Q: What forms and minimum orders do you support?
A: Wire from Ø0.05 mm, tube from OD 1 mm, sheet from 0.1 mm. R&D orders from 10 m / 10 pcs are welcome; production volumes are scheduled through our partner melting and drawing lines.
More answers on our FAQ page →
Request a quote for shape memory alloy
Tel: 0635-2112001 / 19963594228 (WhatsApp) | Email: fykj425@gmail.com | Contact form →
Last Updated:
Liaocheng Feiyan New Material Technology Co., Ltd.
Address: Room 8-1503, 15F, Building 9, Xingguang International Financial Center, Dongchang East Road, Dongcheng Sub-district, Liaocheng Economic and Technological Development Area, Shandong, China
Tel: 0635-2112001 / 19963594228 | Email: fykj425@gmail.com
Copyright © Liaocheng Feiyan New Material Technology Co., Ltd.. All Rights Reserved.