Iridium-bearing scrap is unusual in precious metal recycling: the material is small in volume, high in unit value, and easily misdescribed. A crucible, a wire offcut, a spent catalyst or a mixed sweeps lot can all contain iridium, but they do not behave the same way in a furnace, in a digester or in a dispute. The commercial result therefore depends less on the headline metal price than on the sampling sequence, the assay method and the recovery assumption written into the contract. This article sets out a defensible inspection-to-settlement workflow and explains why a single surface reading is not a settlement result.
Method notes on this site already cover the general case for PGM scrap sampling and assay, what XRF can and cannot detect and why two honest buyers can quote the same catalyst lot 20 percent apart. What follows applies that method specifically to iridium crucibles and other iridium-bearing solids.
| Material form | Typical origin | What the receiving check must establish |
|---|---|---|
| Iridium crucibles and crucible fragments | Crystal growth, high-temperature melting and laboratory crucibles retired from service | Whether the body is solid iridium, an iridium alloy or a coated / composite part; whether liners, welds or deposits are present; gross mass before any cleaning |
| Iridium wire, rod, sheet and offcuts | Fabrication scrap, thermocouple and electrode components | Alloy composition, attached base-metal parts, and whether lots of different origins have been mixed into one drum |
| Iridium-bearing catalysts and coated substrates | Electrolysis anodes, coated titanium electrodes and process catalysts | Substrate identity, coating thickness variation and whether the payable metal sits only at the surface - the reason a surface reading cannot settle the lot |
| Sweeps, residues and slags | Grinding dust, floor sweeps, crucible cleaning residues and refining intermediates | Homogeneity, moisture, free metal particles and the representativeness of a multi-point sample |
This table describes receiving checks, not typical grades. No payable content is assumed here: the iridium fraction can only be established by a representative sample and an appropriate assay of the specific lot.
X-ray fluorescence is a fast and genuinely useful positive material identification tool. It tells an operator whether an incoming part is an iridium-containing alloy and helps sort mixed lots before they are combined. It is not, on its own, a basis for paying for a crucible or a coated substrate. The measurement is shallow and surface-sensitive; a coated or plated part, a crucible with an oxide layer or a lined body can produce a reading that describes the surface rather than the bulk. Light elements and matrix effects further limit what a handheld unit can quantify without preparation and calibration against matched standards.
The practical consequence is procedural. XRF belongs in the sorting and fraud-check stage, before the lot is homogenised. The payable number should come from a laboratory method agreed in the contract - commonly fire assay or a wet-chemical / ICP finish for platinum group metals - applied to a sample that both parties can retain. The XRF analysis guide on this site sets out those limits in detail, and the PGM sampling guide explains why a multi-point sampling plan is what survives a dispute.
These steps are deliberately unglamorous. The same lot can be quoted differently by two honest buyers because they are pricing different ideas of what it contains and what can be recovered from it. A written sequence removes the ambiguity before it becomes a price argument.
For an iridium-bearing lot the payable value is conventionally expressed as:
payable value = (net dry mass) x (measured Ir content) x (agreed recovery rate) x (agreed benchmark price) - (refining, processing and assay fees)
Every term needs a definition in the contract. Net dry mass means the mass after moisture and non-payable attachments are excluded. Measured Ir content is the assay result from the agreed method, not a screening reading. Recovery rate reflects what the specific route can actually return from that material form. Benchmark price must name the instrument, currency and timestamp, because iridium does not track gold and can move independently of the rest of the platinum group - the site's 4 and 5 November 2026 market reviews record iridium rising on hydrogen demand in one session and holding flat in the next. Fees should be visible line items. The pricing guide walks through the same structure for precious metal scrap generally.
This article deliberately gives no worked numerical example. A worked example would require a real assay result, a real recovery rate and a dated iridium quote for a specific lot; inserting illustrative numbers here would invite their reuse as if they were a quotation.
| Document | Why it matters at settlement |
|---|---|
| Material description and photographs as received | Establishes which sub-lots existed before any commingling |
| Gross and net weight record, with moisture note | Defines the mass multiplier in the formula |
| Sampling plan and chain-of-custody record | Makes the assay result defensible if it is challenged |
| Assay certificate and reserve sample reference | Supplies the measured content and enables an umpire determination |
| Benchmark instrument, currency and timestamp | Fixes the price term on a metal that does not follow gold |
| Recovery assumption and fee schedule | Prevents the deductions from appearing as an unexplained discount |
Source and disclaimer: the material identification, sampling and assay practice described on this site in XRF Analysis for Metal and Alloy Verification, PGM Scrap Sampling and Assay, Spent Rhodium Catalyst Recycling, How Precious Metal Scrap Recycling Pricing Works and Precious Metal Recycling Capabilities. This page describes inspection and settlement procedure; it contains no price quotation, no assumed metal content and no guaranteed recovery rate. Any figure used in an actual settlement must come from the assay certificate and the dated benchmark agreed for that specific lot. Prepared by Liaocheng Feiyan New Material Technology Co., Ltd..
No. XRF is a surface-sensitive screening and positive material identification method. It is useful for deciding whether a part is an iridium-containing alloy and for sorting mixed lots, but a crucible with an oxide layer, a coating, a liner or attached base metal can give a reading that describes the surface rather than the bulk. The payable content should come from an agreed laboratory assay - commonly fire assay or a wet-chemical / ICP finish - on a representative sample, with a reserve sample retained.
Payable value is net dry mass multiplied by measured iridium content, multiplied by the agreed recovery rate, multiplied by the agreed benchmark price, minus refining, processing and assay fees. Each term must be defined in the contract: the mass after moisture and attachments, the assay result from the named method, the recovery achievable for that material form, and a benchmark that names its instrument, currency and timestamp.
Iridium clears against its own industrial demand and a concentrated supply base, not the safe-haven flows that drive gold. Market reviews published on this site record iridium rising on hydrogen demand in one session of early November 2026 while holding flat in the next, and platinum group metals moving in opposite directions on the 7 November board. A gold-derived factor would misprice an iridium lot even when the gold quote itself is correct.
A material description with photographs as received, gross and net weight with a moisture note, a written sampling plan and chain-of-custody record, the assay certificate with a reserve sample reference, the benchmark instrument with its currency and timestamp, and a written recovery assumption with a fee schedule. Together these define every term in the settlement formula and make an umpire determination possible if the result is challenged.
Because they may be pricing different assumptions about what the lot contains and what can be recovered, not simply different margins. One may be relying on a surface screening reading, another on a representative multi-point assay; one may assume a recovery rate appropriate to solid metal, another to a coated substrate. The difference is resolved by fixing the sampling plan, assay method, recovery assumption and benchmark in writing before a price is discussed.
Liaocheng Feiyan New Material Technology Co., Ltd.